env:
|
||||
# WiX 3.x candle.exe/light.exe are 32-bit. A runner running as SYSTEM has
|
||||
# %LOCALAPPDATA% = C:\Windows\system32\config\systemprofile\AppData\Local,
|
||||
# and Tauri caches the WiX toolset there. WOW64 redirection then sends a
|
||||
# 32-bit process reading C:\Windows\System32 to C:\Windows\SysWOW64, where
|
||||
# that directory does not exist - so candle.exe cannot see its own folder,
|
||||
# the CLR fails to start, and Tauri reports only "failed to run
|
||||
# candle.exe". The real error is 0x80131700, visible in the Application
|
||||
# event log as ".NET Runtime ... could not be started".
|
||||
#
|
||||
# Verified on our runner: candle.exe -? exits 0 from C:\wixtest and
|
||||
# 0x80131700 from the systemprofile path - same identity, same binary.
|
||||
#
|
||||
# Pointing LOCALAPPDATA outside System32 sidesteps redirection entirely,
|
||||
# and is harmless on a runner that already runs as a normal user.
|
||||
LOCALAPPDATA: C:\actions-runner-cache
|
||||